Sunbird 3000 is Fuji Electric's three-phase solar hybrid inverter, built as a true bi-directional PCU (Power Conditioning Unit) that combines solar charging, grid interaction, and battery backup in one modular unit. Spanning 10 KW to 400 KW, it uses multiple 32-bit DSP controllers with Space Vector Modulation for switching control, and its MPPT charge controller uses incremental conductance algorithms to track the solar array's maximum power point through an IGBT-based, PWM-switched charger. Because it's a true bi-directional design with battery-independent operation, Sunbird 3000 can run as a solar inverter even without batteries connected, while still supporting full grid-assisted battery charging (up to 100%) and a selectable grid/battery priority feature when batteries are present. Its modular internal construction is built specifically to reduce MTTR (mean time to repair), and it carries an inbuilt isolation transformer for galvanic isolation between the solar array/battery side and the grid.
| Spec | Details |
|---|---|
| System Rating | 10, 15, 20, 25, 30, 50, 100, 150, 200, 300, 400 KW |
| Type | Hybrid PCU (Power Conditioning Unit), three-phase output |
| MPPT Voltage Range / Voc | (165–265)/315V to 400–600/720V, depending on rating |
| Maximum Input Current | 67A (10KW) up to 1100A (400KW) |
| Charge Controller | IGBT device MPPT with PWM switching, Space Vector technology |
| Grid Input | 3-phase, 4-wire, 415VAC (+10%/-15%), 50Hz |
| THDi / PF / Harmonic Attenuation | <5% / >0.9 / up to 96% |
| Battery Voltage | 120V, 240V (optional 100KW: 360V & 480VDC), 540V, 600V depending on rating |
| Battery Type Support | SMF / VRLA / Wet Lead Acid / TGel / Li-ion |
| Output Switching | IGBT, 32-bit DSP controller with Space Vector technology |
| Output Waveform | Pure sine wave, 415VAC L-L (240VAC L-N) |
| Voltage Regulation | ±2%, 3-phase 4-wire, 50Hz |
| Load Power Factor | 0.6 lag to 1 (within KVA/KW rating) |
| Overload Capability | 125% (10 min) / 150% (1 min) at nominal output voltage |
| Operating Temperature | Inverter: 0–50°C (storage: 0–70°C) |
| Max Relative Humidity | Up to 95% (non-condensing) |
| Max Altitude (No Derating) | 1,000m (higher altitude per IEC/EN 62040-3) |
| Noise @ 1m | <60 dBA to <70 dBA depending on rating |
| Cooling | Forced air (DC fan, variable speed) |
| Ingress Protection | IP20, indoor, free from corrosive gases & conductive dust |
| Dimensions (W x D x H) | 600×800×1200mm (10–30KW) up to 2150×1000×1750mm (400KW) |
| Cabinet | RAL 7016 texture, Anthracite Grey, bottom-front cable entry |
| Reference Standards | Efficiency: IEC 61683; Environmental: IEC 60068; Inverter testing: IEC 62040 part III; Active filter: IEEE 519; Islanding: IEC 62116 |
Find answers to common questions about our products and solutions.
Sunbird 3000 is Fuji Electric's three-phase, bi-directional solar hybrid inverter (Hybrid PCU) ranging from 10 KW to 400 KW. It combines solar MPPT charging, grid interaction, and battery backup functionality in one modular unit.
Yes. It's a true bi-directional solar inverter with battery-independent operation, meaning it can function as a standard solar inverter even when no battery is connected to the system.
SMF, VRLA, Wet Lead Acid, TGel, and Li-ion batteries are all supported, at battery voltages of 120V, 240V (with a 360V/480VDC option at 100KW), 540V, or 600V depending on the system rating.
MPPT (Maximum Power Point Tracking) is achieved through incremental conductance algorithms, using an IGBT-based charge controller with PWM switching built on Space Vector technology , the same switching approach used on the output/inverter side.
Yes. Battery charging through the grid is supported up to 100%, and a selectable priority feature lets the system be configured to prioritize either grid or battery as the source.
The modular internal design is built specifically to reduce MTTR (mean time to repair) , a fault in one module can typically be addressed by servicing or swapping that module rather than requiring extended downtime for the whole unit.
Yes. It provides PF correction while operating on mains supply (line-interactive) and active harmonic filtering with load correction at 100% load, keeping THDi under 5% and power factor above 0.9.
Under/over-voltage protection across input, output, array, and battery; array and battery reverse-polarity protection; output overload and short-circuit protection; over-temperature protection; MCCB protection on input, output, array, and battery paths; surge protection for grid and array; and an inbuilt isolation transformer at the inverter output.
Efficiency testing per IEC 61683, environmental testing per IEC 60068, inverter testing per IEC 62040 part III, active filter function compliance with IEEE 519, and islanding protection per IEC 62116.