RISH EINE NX 1PH DIGITAL AMMETER , VOLTMETER

  • Display Type: 4-digit bright LED display for clear visibility.

  • Measured Values: Measures AC current and voltage in single-phase systems.

  • Input Range: Current input: 1A/5A via CT; Voltage range: up to 500V AC.

  • Measurement Accuracy: Accuracy: ±0.5% of reading ±1 digit.

  • Power Supply: Operates on 80–270V AC/DC auxiliary supply.

  • Mounting Size: Compact panel mounting with standard dimensions.

  • Key Features: True RMS, overload indication, and front panel programming.

RISH EINE NX 3PH DIGITAL AMMETER , VOLTMETER

  • Display Type: 4-digit bright LED display for phase-wise readings.

  • Measured Values: Measures AC current and voltage in 3-phase systems.

  • Input Range: Current input: 1A/5A via CT; Voltage range: up to 500V AC.

  • Measurement Accuracy: Accuracy: ±0.5% of reading ±1 digit.

  • Power Supply: Operates on 80–270V AC/DC auxiliary supply.

  • Mounting Size: Panel mounting with standard 96 x 96 mm size.

  • Key Features: True RMS, phase indication, and front panel configuration.

RISH EINE+ DIGITAL DC METER 48*96 4-20MA

  • Display Type: 4-digit bright LED display with scalable output indication.

  • Measured Values: Designed to measure DC signals via 4–20mA input.

  • Input Range: Accepts standard 4–20mA DC current input.

  • Measurement Accuracy: High accuracy of ±0.2% of reading ±1 digit.

  • Power Supply: Operates on 80–270V AC/DC auxiliary voltage.

  • Mounting Size: Panel mounting with dimensions 48 x 96 mm.

  • Key Features: Scalable display, overload protection, and compact design.

DELTA ENERGY NX

  • Display Type: Multifunction 4-line LCD display with backlight.

  • Measured Values: Measures voltage, current, power, energy, and frequency.

  • Input Range: Voltage up to 500V AC; current input via 1A/5A CTs.

  • Measurement Accuracy: Class 0.5S accuracy for energy measurement.

  • Power Supply: Auxiliary supply of 80–300V AC/DC.

  • Mounting Size: Panel mounting with 96 x 96 mm standard dimensions.

  • Key Features: RS485 Modbus, load profile logging, and user-friendly interface.

DELTA VAF NX VAF+PF METER HA

  • Display Type: Clear LCD display with backlight for easy reading.

  • Measured Values: Measures Voltage, Current, Frequency, and Power Factor.

  • Input Range: Voltage up to 500V AC; current via 1A/5A CT input.

  • Measurement Accuracy: Class 1 accuracy for voltage and current.

  • Power Supply: Wide auxiliary supply range of 80–270V AC/DC.

  • Mounting Size: Standard 96 x 96 mm panel mounting.

  • Key Features: Measures Voltage, Amperage, Frequency, and Power Factor simultaneously.

RISH DPM FREQUENCY METER

  • Display Type: 4-digit bright LED display for clear frequency readings.

  • Measured Values: Measures AC frequency in Hz for electrical systems.

  • Input Range: Voltage input range typically 80–300V AC.

  • Measurement Accuracy: Accuracy of ±0.2% for frequency measurement.

  • Power Supply: Operates on 80–270V AC/DC auxiliary supply.

  • Mounting Size: Compact panel mounting with standard dimensions.

  • Key Features: True RMS measurement and front panel programmable settings.

RISH EINE + DC AMMETER , VOLTMETER

  • Display Type: 4-digit bright LED display for DC readings.

  • Measured Values: Measures DC current and DC voltage.

  • Input Range: DC current up to specified range (e.g., 0–100A); voltage up to 300V DC.

  • Measurement Accuracy: Accuracy typically ±0.5% of reading ±1 digit.

  • Power Supply: Wide auxiliary supply range, usually 80–270V AC/DC.

  • Mounting Size: Panel mounting with standard sizes (48 x 96 mm or 96 x 96 mm).

  • Key Features: True DC measurement, scalable inputs, and overload indication.

EM 1320 ENERGY METER 60-300U

  • Display Type: 6-digit LCD display for clear energy readings.

  • Measured Values: Measures active energy (kWh) in single-phase systems.

  • Input Range: Voltage range 60–300V AC; current via 1A/5A CT.

  • Measurement Accuracy: Class 1 or better accuracy for energy measurement.

  • Power Supply: Self-powered from measured voltage circuit.

  • Mounting Size: DIN rail mounting for easy panel integration.

  • Key Features: Pulse output, tamper-proof design, and LED indicators.

EM 94 RISH EMDC 6000 (DC ENERGY METER )

  • Display Type: 6-digit LCD display for precise energy measurement.

  • Measured Values: Measures DC energy consumption (kWh).

  • Input Range: Voltage up to 600V DC; current input via shunt or 4-20mA.

  • Measurement Accuracy: High accuracy class 0.5 for energy measurement.

  • Power Supply: Powered from the measured DC voltage line.

  • Mounting Size: Compact panel or DIN rail mounting options.

  • Key Features: Pulse output, data logging, and tamper-resistant design.

OPTIMA VAF METER 60-300U

  • Display Type: 3-line, 3-digit ultra-bright LED display for clear readings.

  • Measured Values: Measures AC voltage, current, frequency, power factor, and more.

  • Input Range: Voltage: 100–500V AC line-to-line; Current: 1A/5A via CT.

  • Measurement Accuracy: Class 1 accuracy for voltage and current measurements.

  • Power Supply: Operates on 40–300V AC/DC auxiliary supply.

  • Mounting Size: Standard panel mount with 96 x 96 mm dimensions.

  • Key Features: True RMS measurement, programmable settings, and optional limit switch.

RISH MASTER 3440 With RS 485

  • Measurement Range: Measures voltage, current, power, energy, frequency, and harmonics up to 31st order.

  • Energy Types: Supports active, reactive, apparent energy, and ampere-hour measurements.

  • Harmonic Analysis: Provides total harmonic distortion (THD) and individual harmonic data.

  • Communication: RS485 Modbus RTU for remote monitoring and integration.

  • Outputs: Optional pulse, relay, and 4-20mA analog outputs.

  • User Settings: Programmable CT/PT ratios and network configuration via panel or Modbus.

  • Compliance: IEC safety and EMC standards; IP54 front panel protection.

RISH MASTER 3450 MFM SWITCH 0.2 WITH RS

  • Measurement: Measures voltage, current, power, energy, frequency, and harmonics up to 31st order.

  • Energy Types: Supports active, reactive, apparent, and ampere-hour energies.

  • Harmonics: Provides THD and individual harmonic data.

  • Communication: RS485 Modbus RTU for remote monitoring.

  • Outputs: Optional pulse, relay, and 4-20mA outputs.

  • User Settings: Programmable CT/PT ratios and network type.

  • Protection: IEC safety standards compliant with IP54 front panel.

Power. Protection. Precision. Performance.